1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-853-1485

5925-00-853-1485

Find complete technical information, availability, and procurement data for: 5925-00-853-1485

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-853-1485 to receive an up to date pricing and availability quote by email.

5925-00-853-1485
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-853-1485
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

1.750 inches maximum body length, single pole type body style, 0.625 inches maximum body width, 0.687 inches nominal center to center distance between terminals parallel to length, 0.315 inches nominal bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.315 inches nominal
Body Length
1.750 inches maximum
Body Width
0.625 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.687 inches nominal
Mounting Surface To Terminal End Distance
1.635 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Ultimate Trip Time Per Pole In Seconds
1.000 minimum and 4.000 maximum single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 0.800 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shockproof and vibrationproof and hermetically sealed
Thread Series Designator
unef
Terminal Type And Quantity
2 wire hook

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-686-9585 No Name Available 07/06/1966
5925-00-826-6601 No Name Available 06/17/1967

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
10015917-003 Circuit Breaker
501A502 Circuit Breaker
9113059 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-853-1485?
The FSCG of the NSN 5925-00-853-1485 is 5925
Does the NSN 5925-00-853-1485 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-853-1485 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-853-1485 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-853-1485 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-853-1485 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

226TTA016M
5935-01-296-8612
Electrical Receptacle Connector
226TTA025A
5910-00-443-8451
Electrolytic Fixed Capacitor
226TTA025B
5910-00-615-5221
Electrolytic Fixed Capacitor
226TTA035A-MX
5910-01-342-7217
Electrolytic Fixed Capacitor
226TTA035M
5910-01-625-8216
Electrolytic Fixed Capacitor
226TTA100M
5910-01-359-7534
Electrolytic Fixed Capacitor
226U2
5950-01-217-1288
Power Transformer
226U3
5950-00-165-3650
Power Transformer
226UM-3
5950-01-300-9807
Power Transformer
226WLN715
5330-01-471-8433
Gasket
226X1054
5331-01-689-8472
O-Ring
226X1055
5331-01-689-8470
O-Ring
226X1068
5330-01-689-5062
Gasket
226X95
3110-00-144-8630
Annular Ball Bearing
226Y1B
7025-01-716-9224
Automatic Data Processin Printer