1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-844-9475

5925-00-844-9475

Find complete technical information, availability, and procurement data for: 5925-00-844-9475

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-844-9475 to receive an up to date pricing and availability quote by email.

5925-00-844-9475
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-844-9475
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

2.189 inches nominal overall length, 0.250 inches nominal bushing length, single pole type body style, 0.750 inches maximum body width, 3.015 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Overall Length
2.189 inches nominal
Bushing Length
0.250 inches nominal
Body Length
3.015 inches nominal
Body Width
0.750 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.470 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.862 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.250 inches maximum
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
70.0 amperes ac and 70.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac and 6000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct and 65.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Unpackaged Unit Weight
113.0 grams nominal
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
160-001-70 Circuit Breaker
LS7507-70 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-844-9475?
The FSCG of the NSN 5925-00-844-9475 is 5925
Does the NSN 5925-00-844-9475 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-844-9475 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-844-9475 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-844-9475 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-844-9475 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

A78935
2910-00-036-5434
Tube
A78936
2910-00-036-5435
Tube
A78937
2910-00-036-5436
Tube
A78937-1
1680-01-362-5852
Actuator Seal Plug
A78938
4710-00-036-5437
Metallic Tube
A78939
2910-00-036-5438
Tube
A78942
2910-00-036-5441
Tube
A78943
2910-00-036-5323
Tube
A78944
5340-00-205-4797
Plain Solid Disk
A78945
2910-00-036-5325
Tube
A78947
2910-00-036-5327
Tube
A78952-014
5999-01-361-3646
Electronic Shielding Gasket
A78952-111
5999-01-361-3644
Electronic Shielding Gasket
A78952-112
5999-01-361-3647
Electronic Shielding Gasket
A78952-12
5999-01-361-3645
Electronic Shielding Gasket