1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-841-3558

5925-00-841-3558

Find complete technical information, availability, and procurement data for: 5925-00-841-3558

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-841-3558 to receive an up to date pricing and availability quote by email.

5925-00-841-3558
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-841-3558
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

0.735 inches minimum and 0.765 inches maximum body width, single pole type body style, 2.047 inches minimum and 2.077 inches maximum distance between centerlines of mounting facilities parallel to body length, 2.485 inches minimum and 2.515 inches maximum body length, 1.925 inches minimum and 1.955 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.485 inches minimum and 2.515 inches maximum
Body Width
0.735 inches minimum and 0.765 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.047 inches minimum and 2.077 inches maximum
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Boss Height
0.125 inches minimum and 0.155 inches maximum
Mounting Surface To Terminal End Distance
2.775 inches minimum and 2.955 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac and 2.5 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 2000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 10.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
salt spray proof and shock resistant and vibration resistant and moisture resistant
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
Switch Voltage Rating And Type In Volts
115.0 ac and 50.0 dc
Unpackaged Unit Weight
0.312 pounds nominal
Frequency In Hertz
60.0 single location
Material
plastic case
Test Data Document
05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-808-8438 No Name Available 04/25/1969

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
315C861G15 Circuit Breaker
70-132-8MG6 Circuit Breaker
711570-034 Circuit Breaker
711570-34REVC Circuit Breaker
AM12HKMG3-2-5-50-250VAC4 Circuit Breaker
AM12HKMG3-2-5AMP115VACCURVE4 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-841-3558?
The FSCG of the NSN 5925-00-841-3558 is 5925
Does the NSN 5925-00-841-3558 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-841-3558 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-841-3558 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-841-3558 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-841-3558 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

58A5A100-1
5945-00-556-7940
Electromagnetic Relay
58A5A100-2
5945-00-617-6971
Electromagnetic Relay
58A5A100-4
5945-00-556-7931
Electromagnetic Relay
58A5A100-5
5945-00-061-2686
Electromagnetic Relay
58A5A100-6
5945-00-556-7931
Electromagnetic Relay
58A5A100-8
5945-00-815-9386
Electromagnetic Relay
58A5A101-1
5935-00-681-5819
Plug-in Electronic Compon Socket
58A5A101-2
5935-00-557-4422
Plug-in Electronic Compon Socket
58A5A103-20
5910-00-723-5616
Electrolytic Fixed Capacitor
58A5A103-3
5910-00-833-7971
Electrolytic Fixed Capacitor
58A5A103-36
5910-00-820-4297
Electrolytic Fixed Capacitor
58A5A103-45
5910-00-985-2081
Electrolytic Fixed Capacitor
58A5A103-7
5910-00-812-3726
Electrolytic Fixed Capacitor
58A5A103-8
5910-00-843-3353
Electrolytic Fixed Capacitor
58A5A104
5950-00-631-8939
Pulse Transformer