DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-811-8205 to receive an up to date pricing and availability quote by email.

5925-00-811-8205
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-811-8205
Item Name Code
00136
Assigment Date
03/27/1968 (58 years ago)

1.250 inches nominal body width, 2.000 inches nominal overall length, 0.190 inches nominal unthreaded mounting hole diameter, single pole type body style, 0.906 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Overall Length
2.000 inches nominal
Body Width
1.250 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
Unthreaded Mounting Hole Diameter
0.190 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.574 inches nominal
Mounting Surface To Terminal End Distance
1.266 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 unthreaded hole
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
600.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Internal Trip Release Configuration
series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 minimum at 200 pct and 70.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shock resistant
Trip Release Ambient Temp Rating
77.0 fahrenheit nominal single location
Material
plastic case
Terminal Type And Quantity
2 tab w/screw

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-449-8221 No Name Available 12/01/1977

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
11647624 Circuit Breaker
5925008118205 Circuit Breaker
6010651-002 Circuit Breaker
7565721-008 Circuit Breaker
PDA-3 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-811-8205?
The FSCG of the NSN 5925-00-811-8205 is 5925
Does the NSN 5925-00-811-8205 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-811-8205 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-811-8205 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-811-8205 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-811-8205 was assigned to the Federal Catalog?
It was assigned 58 years ago, on Wed, Mar 27, 1968

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

8080001435
5998-01-193-1479
Printed Wiring Board
8080001436
5998-01-190-6572
Printed Wiring Board
8080001444
5998-01-190-6576
Printed Wiring Board
8080001452
5330-01-197-6321
Gasket
8080001454
5998-01-190-6577
Printed Wiring Board
8080001455
5998-01-190-6592
Printed Wiring Board
8080001457
5998-01-190-6593
Printed Wiring Board
8080001462
5998-01-190-6590
Printed Wiring Board
8080001464
5998-01-190-6597
Printed Wiring Board
8080001466-1
5998-01-190-6586
Printed Wiring Board
8080001472
5998-01-190-6595
Printed Wiring Board
8080001474
5998-01-190-6614
Printed Wiring Board
8080001481-1
5998-01-190-6601
Printed Wiring Board
8080001482
5998-01-190-8042
Printed Wiring Board
8080001484
5998-01-190-9060
Printed Wiring Board