1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-755-5996

5925-00-755-5996

Find complete technical information, availability, and procurement data for: 5925-00-755-5996

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-755-5996 to receive an up to date pricing and availability quote by email.

5925-00-755-5996
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-755-5996
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

0.250 inches nominal bushing length, 2.203 inches nominal body length, 0.906 inches nominal center to center distance between terminals parallel to length, 0.750 inches nominal body width, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.250 inches nominal
Body Length
2.203 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.797 inches nominal
Mounting Surface To Terminal End Distance
1.312 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac and 20.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac and 4000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 60.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Unpackaged Unit Weight
0.209 pounds nominal
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
52B1074-2 Circuit Breaker
7270-7-20 Circuit Breaker
D7270-7-20 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-755-5996?
The FSCG of the NSN 5925-00-755-5996 is 5925
Does the NSN 5925-00-755-5996 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-755-5996 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-755-5996 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-755-5996 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-755-5996 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

12364375
2520-01-421-5133
Propeller Shaft With Universal J
12364377
3110-00-100-0337
Tapered Roller Bearing Cup
12364377-1
3110-00-100-0684
Tapered Roller Cone and Rollers
12364377-2
3110-00-100-0337
Tapered Roller Bearing Cup
12364378
2530-01-419-7047
Vehicular Wheel Hub
12364379-1
3110-00-100-0271
Tapered Roller Cone and Rollers
12364379-2
3110-00-100-0323
Tapered Roller Bearing Cup
12364381
5930-01-425-2960
Switch Box
12364382
6110-01-422-2580
Distribution Box
12364383
2530-01-439-3505
Pneumatic Accumulator
12364384
4820-01-416-8522
Directional Control Linear Valve
12364385-1
4030-01-420-8862
Shackle
12364386
4030-01-433-2301
Shackle
12364389
4010-01-421-2793
Single Leg Wire Rope Assembly
12364391
2910-01-411-4864
Engine Fuel Tank