1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-676-1797

5925-00-676-1797

Find complete technical information, availability, and procurement data for: 5925-00-676-1797

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-676-1797 to receive an up to date pricing and availability quote by email.

5925-00-676-1797
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-676-1797
Item Name Code
00136
Assigment Date
01/01/1963 (63 years ago)

multipole-single actuator type body style, 4.062 inches nominal body height, 8.094 inches nominal center to center distance between terminals parallel to length, 4.125 inches nominal body width, 9.375 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
9.375 inches nominal
Body Width
4.125 inches nominal
Body Height
4.062 inches nominal
Center To Center Distance Between Terminals Parallel To Length
8.094 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
Unthreaded Mounting Hole Diameter
0.250 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.500 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
Boss Height
0.250 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
70.0 amperes ac and 70.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac and 10000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
18.000 minimum at 200 pct and 45.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
31-0096 Circuit Breaker
NF631070 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-676-1797?
The FSCG of the NSN 5925-00-676-1797 is 5925
Does the NSN 5925-00-676-1797 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-676-1797 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-676-1797 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-676-1797 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-676-1797 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

C2DB11654A1
5930-00-759-7355
Push-Pull Switch
C2DB52S-FO
5935-01-375-0706
Electrical Receptacle Connector
C2DB52SF172G
5935-01-300-0439
Electrical Plug Connector
C2DB52SG
5935-01-393-7235
Electrical Receptacle Connector
C2DBF52P
5935-00-498-7675
Electrical Receptacle Connector
C2DC79P-36
5935-01-210-9861
Electrical Receptacle Connector
C2DD100S
5935-00-419-0499
Electrical Receptacle Connector
C2DD100S-.190
5935-01-306-7507
Electrical Plug Connector
C2DE-8255-A
5330-00-484-6255
Gasket
C2DE195F172
5935-01-204-1390
Electrical Receptacle Connector
C2DE19PF173
5935-01-211-1546
Electrical Receptacle Connector
C2DE19SF171
5935-00-113-2460
Electrical Receptacle Connector
C2DE8255A
5330-00-484-6255
Gasket
C2DEF19P
5935-01-076-3664
Electrical Receptacle Connector
C2DF1002A
2920-00-759-7368
Engine Accessory Generator