DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-617-2994 to receive an up to date pricing and availability quote by email.

5925-00-617-2994
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-617-2994
Item Name Code
00136
Assigment Date
01/01/1961 (65 years ago)

0.750 inches nominal body width, 2.500 inches nominal body length, single pole type body style, 1.938 inches nominal center to center distance between terminals parallel to length, 2.062 inches nominal distance between centerlines of mounting facilities parallel to body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.471 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc third location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 0.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof and fungus proof
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
1226277 Circuit Breaker
86-174 Circuit Breaker
AM12RSKMG3 Circuit Breaker
AM12RSKMG6-50-50VDC-CURVE5 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-617-2994?
The FSCG of the NSN 5925-00-617-2994 is 5925
Does the NSN 5925-00-617-2994 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-617-2994 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-617-2994 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-617-2994 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-617-2994 was assigned to the Federal Catalog?
It was assigned 65 years ago, on Sun, Jan 1, 1961

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

G494565-141
5962-01-361-0143
Digital Microcircuit
G494565-144
5962-01-363-6472
Digital Microcircuit
G494565-146
5962-01-363-2453
Digital Microcircuit
G494565-147
5962-01-363-2455
Digital Microcircuit
G494565-151
5962-01-370-3162
Digital Microcircuit
G494565-152
5962-01-363-4752
Digital Microcircuit
G494565-155
5962-01-369-1208
Memory Microcircuit
G494565-156
5962-01-370-3163
Memory Microcircuit
G494565-157
5962-01-369-5293
Memory Microcircuit
G494565-158
5962-01-363-6199
Memory Microcircuit
G494565-164
5962-01-361-0139
Linear Microcircuit
G494565-165
5962-01-369-1199
Digital Microcircuit
G494565-166
5962-01-368-6578
Linear Microcircuit
G494565-167
5962-01-362-7010
Digital Microcircuit
G494565-168
5962-01-360-1356
Digital Microcircuit