1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-615-7267

5925-00-615-7267

Find complete technical information, availability, and procurement data for: 5925-00-615-7267

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-615-7267 to receive an up to date pricing and availability quote by email.

5925-00-615-7267
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-615-7267
Item Name Code
00136
Assigment Date
01/01/1963 (63 years ago)

3.188 inches nominal body height, 5.250 inches nominal center to center distance between terminals parallel to length, 6.312 inches nominal body length, multipole-single actuator type body style, 4.125 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.312 inches nominal
Body Width
4.125 inches nominal
Body Height
3.188 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.250 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
Unthreaded Mounting Hole Diameter
0.188 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.880 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
Boss Height
0.125 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Trip Delay Time In Seconds Per Rated Continuous Current
35.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
general purpose
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-581-1933 No Name Available 05/01/1976

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
TF136M1100 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-615-7267?
The FSCG of the NSN 5925-00-615-7267 is 5925
Does the NSN 5925-00-615-7267 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-615-7267 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-615-7267 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-615-7267 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-615-7267 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

21-90-11
5920-00-283-1321
Aircraf Electrostatic Discharger
21-90-134
2640-01-138-1576
Valve Core Remover
21-90-33
5920-01-434-8504
Aircraf Electrostatic Discharger
21-90-34
5920-01-260-6324
Electrostatic Discharger
21-900010
3130-01-352-2123
Bearing Housing Liner
21-900011
3110-01-352-2122
Annular Ball Bearing
21-900048-2
5935-01-032-3494
Electrical Receptacle Connector
21-900048-3
5935-01-032-3492
Electrical Receptacle Connector
21-900074-001
5935-00-833-5719
Connector Adapter
21-900075-001
5935-00-833-5720
Connector Adapter
21-900075-020
5915-01-331-3866
Radio Frequency Interfere Filter
21-900075-023
5915-01-331-3061
Radio Frequency Interfere Filter
21-900075-024
5915-01-331-3062
Radio Frequency Interfere Filter
21-900075-025
5915-01-331-3869
Radio Frequency Interfere Filter
21-900075-026
5915-01-394-3643
Radio Frequency Interfere Filter