5925-00-593-4648

Find complete technical information, availability, and procurement data for: 5925-00-593-4648

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-593-4648 to receive an up to date pricing and availability quote by email.

5925-00-593-4648
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-593-4648
Item Name Code
00136
Assigment Date
01/08/1975 (51 years ago)

1.938 inches nominal center to center distance between terminals parallel to length, 2.280 inches maximum body width, 2.500 inches nominal body length, multipole-multiple actuator type body style, 0.750 inches nominal center to center distance between terminals parallel to width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.500 inches nominal
Body Width
2.280 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Boss Height
0.145 inches nominal
Mounting Surface To Terminal End Distance
2.485 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
6 threaded hole
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Ultimate Trip Time Per Pole In Seconds
10.000 nominal all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 nominal at 125 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Frequency In Hertz
400.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
989C976H02 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-593-4648?
The FSCG of the NSN 5925-00-593-4648 is 5925
Does the NSN 5925-00-593-4648 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-593-4648 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-593-4648 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-593-4648 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-593-4648 was assigned to the Federal Catalog?
It was assigned 51 years ago, on Wed, Jan 8, 1975

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

54161
5962-00-369-7641
Digital Microcircuit
54161-1
5950-00-296-1319
Reactor
54161-4345M
5342-00-051-8885
Grooved Clamp Coupling
54161/BEA
5962-01-330-7340
Digital Microcircuit
54161/BEJC
5962-00-369-7641
Digital Microcircuit
541610-2
5841-00-907-3079
Holdout Bar Bracket
541611
2240-00-651-1561
Seat
5416118
4720-01-678-0420
Preformed Hose
54161301
5998-01-068-4555
Circuit Card Assembly
541614
4730-00-273-3398
Pipe to Hose Straight Adapter
541614-1
5995-00-853-3551
Cable Clamp
541614-3
5995-00-853-3551
Cable Clamp
541614-4
5340-00-878-8982
Retaining Strap
541614TYPE1
4730-00-273-3398
Pipe to Hose Straight Adapter
541615
4730-00-273-3399
Pipe to Hose Straight Adapter