DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-583-7613 to receive an up to date pricing and availability quote by email.

5925-00-583-7613
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-583-7613
Item Name Code
00136
Assigment Date
01/01/1963 (63 years ago)

2.250 inches maximum body length, 0.250 inches nominal bushing length, multipole-single actuator type body style, 2.125 inches maximum body height, 2.203 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.250 inches nominal
Body Length
2.250 inches maximum
Body Width
2.203 inches maximum
Body Height
2.125 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.188 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.743 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.486 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
220.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 minimum at 200 pct and 100.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
shockproof and tamperproof and fungus resistant
Trip Release Ambient Temp Rating
77.0 fahrenheit nominal all locations
Unpackaged Unit Weight
3.000 ounces nominal
Frequency In Hertz
400.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
410141-5 Circuit Breaker
D6760-1-5 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-583-7613?
The FSCG of the NSN 5925-00-583-7613 is 5925
Does the NSN 5925-00-583-7613 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-583-7613 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-583-7613 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-583-7613 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-583-7613 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

378-0466
6625-00-189-7054
Voltmeter
378-0467
6625-00-189-7015
Ammeter
378-0468
6625-00-189-7056
Voltmeter
378-0469
6625-00-189-7025
Voltmeter
378-0470
6625-00-189-7026
Ammeter
378-0471
6625-00-423-5345
Ammeter
378-0472
6625-01-318-4651
Voltmeter
378-0475
6625-00-479-3644
Voltmeter
378-0476
6625-00-479-3645
Ammeter
378-0477
6625-00-494-6862
Ammeter
378-0484-801
4320-01-424-3129
Hydraulic Motor Safety Coupling
378-0489-001
3110-01-436-9177
Annular Ball Bearing
378-0490
6625-00-223-8990
Ammeter
378-0491
6625-00-223-8991
Voltmeter
378-0492
6625-00-223-8992
Voltmeter