1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-583-1910

5925-00-583-1910

Find complete technical information, availability, and procurement data for: 5925-00-583-1910

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-583-1910 to receive an up to date pricing and availability quote by email.

5925-00-583-1910
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-583-1910
Item Name Code
00136
Assigment Date
01/01/1963 (63 years ago)

0.813 inches nominal center to center distance between terminals parallel to length, single pole type body style, 0.750 inches nominal body width, 1.750 inches nominal overall length, 0.150 inches nominal unthreaded mounting hole diameter

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Overall Length
1.750 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.813 inches nominal
Unthreaded Mounting Hole Diameter
0.150 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.375 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
0.938 inches nominal
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
2 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
750.0 milliamperes ac and 750.0 milliamperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac and 2000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location
Reset Method
automatic
Internal Trip Release Configuration
series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 100.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof and corrosion resistant and vibration resistant and shock resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Unpackaged Unit Weight
1.250 ounces nominal
Frequency In Hertz
60.0 single location
Material
plastic case
Terminal Type And Quantity
2 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
6756-1-3/4 Circuit Breaker
D6756-1 3-4 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-583-1910?
The FSCG of the NSN 5925-00-583-1910 is 5925
Does the NSN 5925-00-583-1910 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-583-1910 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-583-1910 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-583-1910 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-583-1910 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

CR7M1KP0RM1PCT
5905-01-094-9840
Composition Fixed Resistor
CR7RA22EA
5945-01-393-7927
Hybrid Relay
CR7RA40EA
5945-01-407-1592
Electromagnetic Relay
CR7S7-3-2
5320-00-118-6701
Blind Rivet
CR7U
5955-00-667-2674
Quartz Crystal Unit
CR7X5370
5910-01-473-6237
Electrolytic Fixed Capacitor
CR7XR40
5945-01-395-8669
Relay Contact Set
CR7Z1003
5945-00-786-2553
Electromagnetic Relay
CR7Z1003TN
5945-00-786-2553
Electromagnetic Relay
CR7ZAL
6110-01-391-1850
Magnetic Contactor
CR8
2520-01-166-3097
Vehicular Torque Converter
CR8-1
3110-00-198-2231
Needle Bearing Cam Follower
CR8-120U-O-A-AUUE
4320-01-446-5952
Centrifugal Pump Unit
CR8-120U-U-G-A-
4320-01-446-5952
Centrifugal Pump Unit
CR8-1CP
3110-00-277-0700
Needle Bearing Cam Follower