DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-496-3638 to receive an up to date pricing and availability quote by email.

5925-00-496-3638
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-496-3638
Item Name Code
00136
Assigment Date
10/03/1969 (56 years ago)

4.062 inches nominal body height, 13.094 inches nominal body length, multipole-single actuator type body style, 8.250 inches nominal body width, 10.874 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
13.094 inches nominal
Body Width
8.250 inches nominal
Body Height
4.062 inches nominal
Center To Center Distance Between Terminals Parallel To Length
10.874 inches nominal
Center To Center Distance Between Terminals Parallel To Width
2.750 inches nominal
Unthreaded Mounting Hole Diameter
0.312 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.530 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.750 inches nominal
Boss Height
0.250 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
300.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
22000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Ultimate Trip Time Per Pole In Seconds
540.000 minimum and 7200.000 maximum all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Trip Delay Time In Seconds Per Rated Continuous Current
85.000 minimum at 200 pct and 540.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
50.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
LAB3300V Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-496-3638?
The FSCG of the NSN 5925-00-496-3638 is 5925
Does the NSN 5925-00-496-3638 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-496-3638 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-496-3638 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-496-3638 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-496-3638 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Fri, Oct 3, 1969

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

SL-8602-041-026
6110-01-290-0413
Motor Starter
SL-8602-041-031
6110-01-250-4519
Motor Starter
SL-8602-041-032
6110-01-295-5323
Motor Starter
SL-8602-041-033
6110-01-295-5324
Motor Starter
SL-8602-041-038
6110-01-250-4509
Motor Controller
SL-8602-041-039
6110-01-279-1991
Motor Controller
SL-8602-041-040
6110-01-278-2400
Motor Controller
SL-8602-041-042
6110-01-321-3160
Motor Controller
SL-8602-041-044
6110-01-280-8917
Motor Controller
SL-8602.041.045
6110-01-282-4564
Motor Controller
SL-8602-041-048
6110-01-284-4537
Motor Controller
SL-8602-041-049
6110-01-321-2714
Motor Controller
SL-8602-041-050
6110-01-288-9816
Motor Starter
SL-8602-041-051
6110-01-288-9819
Motor Starter
SL-8602-041-052
6110-01-292-1990
Motor Starter