1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-494-9565

5925-00-494-9565

Find complete technical information, availability, and procurement data for: 5925-00-494-9565

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-494-9565 to receive an up to date pricing and availability quote by email.

5925-00-494-9565
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-494-9565
Item Name Code
00136
Assigment Date
06/11/1969 (57 years ago)

An item having wrenching facilities on one end and a threaded connection of one type within an externally threaded connection of another type. One connection must have machine threads not designed for any type of tube or tube fitting.

2.375 inches nominal body height, 2.875 inches nominal body length, 1.000 inches nominal center to center distance between terminals parallel to width, multipole-multiple actuator type body style, 3.000 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.875 inches nominal
Body Width
3.000 inches nominal
Body Height
2.375 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.000 inches nominal
Boss Height
0.187 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
6 terminal
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Trip Release Ambient Temp Rating
40.0 celsius maximum all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
3 clip and 3 compression

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-01-030-6240 No Name Available 09/01/1986

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
8035434-4 Circuit Breaker
EQ-P9434 Circuit Breaker
QP3B040 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-494-9565?
The FSCG of the NSN 5925-00-494-9565 is 5925
Does the NSN 5925-00-494-9565 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-494-9565 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-494-9565 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-494-9565 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-494-9565 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Wed, Jun 11, 1969

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

226199-000
5962-00-320-4401
Digital Microcircuit
226199-1
2910-01-294-6063
Metering and Distribut Parts Kit
2261A
5985-00-975-4038
Waveguide Adapter
2261A003
6760-01-519-0758
Repeatin Photographic Flash Unit
2261A1
1660-00-658-5047
Air Valve Assy
2261A16
1660-00-673-7336
Gate Assy
2261E
5331-00-698-8751
O-Ring
2261H
5310-01-065-8798
Lock Washer
2261HX
5310-01-065-8798
Lock Washer
2261HX1
5310-00-080-9786
Lock Washer
2261P
5310-00-393-3476
Round Plain Nut
2262
4730-00-829-9806
Fluid Flow Restrictor
2262-
6510-01-701-3821
Gauze Bandage
2262-0-017
5340-01-474-4042
Wall Mount System
2262-1-5-MP9
5935-01-007-6440
Electrical Receptacle Connector