5925-00-484-4566
Find complete technical information, availability, and procurement data for: 5925-00-484-4566
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-484-4566 to receive an up to date pricing and availability quote by email.
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.
4.120 inches minimum and 4.140 inches maximum body width, 3.370 inches minimum and 3.390 inches maximum body height, 5.990 inches minimum and 6.010 inches maximum body length, 5.115 inches minimum and 5.135 inches maximum center to center distance between terminals parallel to length, multipole-single actuator type body style
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Body Style
- multipole-single actuator type
- Body Length
- 5.990 inches minimum and 6.010 inches maximum
- Body Width
- 4.120 inches minimum and 4.140 inches maximum
- Body Height
- 3.370 inches minimum and 3.390 inches maximum
- Center To Center Distance Between Terminals Parallel To Length
- 5.115 inches minimum and 5.135 inches maximum
- Center To Center Distance Between Terminals Parallel To Width
- 1.370 inches minimum and 1.390 inches maximum
- Unthreaded Mounting Hole Diameter
- 0.180 inches minimum and 0.200 inches maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
- 3.449 inches minimum and 3.469 inches maximum
- Switch Contact Arrangement
- single pole, double throw
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
- 1.370 inches minimum and 1.390 inches maximum
- Fragility Factor
- moderately rugged
- Boss Height
- 0.110 inches minimum and 0.130 inches maximum
- Pole Quantity
- 3
- Mounting Facility Type And Quantity
- 4 unthreaded hole
- Storage Type
- general purpose warehouse
- Special Handling Feature
- magnetic
- Maximum Continuous Load Current Rating Per Pole
- 20.0 amperes ac all locations
- Operating Voltage Type And Rating Per Pole In Volts
- 600.0 ac all locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 18000.0 ac all locations
- Circuit Protection Type
- overcurrent all locations
- Trip Release Method
- thermal-magnetic all locations
- Trip Release Characteristic
- time delay all locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 125.0 all locations
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 1 toggle
- Actuator Function
- trip-reset
- Actuator Position Designation
- at pole two
- Auxiliary Switch Function And Quantity
- 1 alarm
- Switch Location And Position Designation
- internal at pole three
- Trip Delay Time In Seconds Per Rated Continuous Current
- 30.000 minimum at 200 pct and 70.000 maximum at 200 pct all locations
- Inclosure Protection Type For Which Designed
- fungus resistant
- Trip Release Ambient Temp Rating
- 40.0 celsius nominal all locations
- Switch Terminal Type
- tab, solder lug
- Switch Current Rating And Type In Amps
- 5.0 ac
- Switch Voltage Rating And Type In Volts
- 240.0 ac
- Frequency In Hertz
- 60.0 all locations
- Material
- plastic case
- Terminal Type And Quantity
- 6 compression
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 4976D04G35 | Circuit Breaker |
| 711532-1 | Circuit Breaker |
| FD3020 WITH A1X1LB | Circuit Breaker |
| HFB3020 | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-00-484-4566?
Does the NSN 5925-00-484-4566 have a Schedule B code assigned?
Does NSN 5925-00-484-4566 require demilitarization?
Does NSN 5925-00-484-4566 contain precious materials?
Does NSN 5925-00-484-4566 contain hazardous materials?
When the NSN 5925-00-484-4566 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing