1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-432-6277

5925-00-432-6277

Find complete technical information, availability, and procurement data for: 5925-00-432-6277

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-432-6277 to receive an up to date pricing and availability quote by email.

5925-00-432-6277
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-432-6277
Item Name Code
00136
Assigment Date
05/10/1971 (55 years ago)

5.250 inches nominal center to center distance between terminals parallel to length, multipole-single actuator type body style, 3.380 inches nominal body height, 4.125 inches nominal body width, 6.310 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.310 inches nominal
Body Width
4.125 inches nominal
Body Height
3.380 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.250 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.380 inches nominal
Unthreaded Mounting Hole Diameter
0.178 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.880 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.380 inches nominal
Boss Height
0.240 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
70.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
85.000 minimum at 200 pct and 350.000 maximum at 200 pct all locations
Trip Release Ambient Temp Rating
50.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 tab, solder lug

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-984-3320 No Name Available 02/01/2009

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
TED134C5070 Circuit Breaker
TED134C5070WL Circuit Breaker
TEF134C5070XL Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-432-6277?
The FSCG of the NSN 5925-00-432-6277 is 5925
Does the NSN 5925-00-432-6277 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-432-6277 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-432-6277 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-432-6277 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-432-6277 was assigned to the Federal Catalog?
It was assigned 55 years ago, on Mon, May 10, 1971

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

MT87L
2530-00-733-9419
Rod
MT88
2530-00-733-9420
Rod Operating Cable
MT8804AE
5962-01-143-3731
Digital Microcircuit
MT8804BE
5962-01-143-3731
Digital Microcircuit
MT8808A3210801
4720-01-441-3947
Nonmetallic Tubing
MT8812AE
5962-01-326-8715
Digital-Linear Microcircuit
MT8840
5330-00-147-6309
Preformed Packing
MT8865XC
5962-01-270-5683
Digital Microcircuit
MT8865XE
5962-01-270-5683
Digital Microcircuit
MT8870AC
5962-01-091-4846
Linear Microcircuit
MT8870BC
5962-01-290-0311
Digital Microcircuit
MT8870CC
5962-01-290-0311
Digital Microcircuit
MT88A
4910-01-314-1328
Engine Analyzer Magnetic Pickup
MT89
4910-01-314-1329
Engine Analyzer Magnetic Pickup
MT89030100-70
5945-01-454-5725