Find complete technical information, availability, and procurement data for: 5925-00-429-2690

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-429-2690 to receive an up to date pricing and availability quote by email.

5925-00-429-2690
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-429-2690
Item Name Code
00136
Assigment Date
01/01/1963 (63 years ago)

2.820 inches minimum and 2.840 inches maximum body height, 4.370 inches minimum and 4.390 inches maximum center to center distance between terminals parallel to length, 1.020 inches minimum and 1.040 inches maximum body width, single pole type body style, 4.740 inches minimum and 4.760 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
4.740 inches minimum and 4.760 inches maximum
Body Width
1.020 inches minimum and 1.040 inches maximum
Body Height
2.820 inches minimum and 2.840 inches maximum
Center To Center Distance Between Terminals Parallel To Length
4.370 inches minimum and 4.390 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
Fragility Factor
moderately rugged
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.500 minimum at 200 pct and 60.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof and fungus proof
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
1 compression and 1 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
0411-35 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-429-2690?
The FSCG of the NSN 5925-00-429-2690 is 5925
Does the NSN 5925-00-429-2690 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-429-2690 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-429-2690 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-429-2690 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-429-2690 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

10109829
5310-01-151-0649
Gang C Self-Locking Nut Assembly
1010983
8415-01-591-4920
Shooter's Glove
10109830
5310-01-151-0651
Plate Nut Spacer
10109831
5310-01-151-8346
Plate Self-Locking Nut
10109832
5310-01-152-3584
Flat Washer
10109833
5310-01-152-8198
Knurled Self-Locking Nut
10109834
5310-01-152-9355
Flat Washer
10109835
5310-01-153-9303
Key Washer
10109836
5310-01-154-2601
Hexagon Self-Locking Nut
10109837
5310-01-154-2602
Hexagon Self-Locking Nut
10109837-101
5915-01-283-8497
Band Pass Filter
10109838
5310-01-154-4336
Flat Washer
10109838-101
5962-01-293-8409
Linear Microcircuit
10109839
5310-01-154-4337
Flat Washer
10109839-101
5962-01-293-9221
Linear Microcircuit