5925-00-403-2571

Find complete technical information, availability, and procurement data for: 5925-00-403-2571

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-403-2571 to receive an up to date pricing and availability quote by email.

5925-00-403-2571
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-403-2571
Item Name Code
00136
Assigment Date
06/05/1970 (56 years ago)

3.375 inches nominal body height, 5.562 inches nominal center to center distance between terminals parallel to length, multipole-single actuator type body style, 6.500 inches nominal body length, 4.125 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.500 inches nominal
Body Width
4.125 inches nominal
Body Height
3.375 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.562 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
Unthreaded Mounting Hole Diameter
0.188 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
Boss Height
0.125 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac and 20.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100000.0 ac and 100000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
50.000 minimum at 200 pct and 130.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
50.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
4968D87G13 Circuit Breaker
FA3020PV Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-403-2571?
The FSCG of the NSN 5925-00-403-2571 is 5925
Does the NSN 5925-00-403-2571 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-403-2571 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-403-2571 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-403-2571 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-403-2571 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Fri, Jun 5, 1970

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

A1353MPC49
5315-00-149-2516
Headed Straight Pin
A1353MPC55
3040-00-149-2515
Shouldered Shaft
A1353MPC56
3040-00-163-0400
Spur Gearshaft
A1353MPC58
3020-00-446-5447
Spur Gear
A1353MPC59
5330-00-336-9388
Packing Retainer
A1353MPC67
5360-00-200-2355
Compression Helical Spring
A1353MPC68
5360-00-292-1129
Compression Helical Spring
A1353MPC71
5365-00-163-0366
Friction Block Spacer
A1353MPC80
5360-00-292-1132
Compression Helical Spring
A1353MPC83
5360-00-316-5347
Compression Helical Spring
A1353MPC85
4330-00-336-9392
Fluid Filter Element
A1353MPC89
5360-00-030-3175
Compression Helical Spring
A1353MPC97
5315-00-276-6627
Machine Key
A1353PC89
5360-00-030-3175
Compression Helical Spring
A1354
2530-00-774-4326
Bar