1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-400-9024

5925-00-400-9024

Find complete technical information, availability, and procurement data for: 5925-00-400-9024

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-400-9024 to receive an up to date pricing and availability quote by email.

5925-00-400-9024
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-400-9024
Item Name Code
00136
Assigment Date
11/19/1969 (56 years ago)

multipole-single actuator type body style, 1.250 inches maximum body width, 0.375 inches nominal bushing length, 1.500 inches maximum body length, 0.875 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.375 inches nominal
Body Length
1.500 inches maximum
Body Width
1.250 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.780 inches maximum
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct and 4.000 maximum at 100 pct all locations
Inclosure Protection Type For Which Designed
general purpose and hermetically sealed
Unpackaged Unit Weight
3.400 ounces nominal
Frequency In Hertz
400.0 all locations
Material
plastic case
Thread Series Designator
unef
Terminal Type And Quantity
4 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
1943379-20 Circuit Breaker
HE2-C3-2-250-400-1 Circuit Breaker
HE2C3-2A250AC400HZ1 Circuit Breaker
SM33-2-250VAC400C1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-400-9024?
The FSCG of the NSN 5925-00-400-9024 is 5925
Does the NSN 5925-00-400-9024 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-400-9024 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-400-9024 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-400-9024 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-400-9024 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Wed, Nov 19, 1969

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

F116263 ITEM 36
6220-01-619-5293
Indicator Light
F116263 ITEM 4
6220-01-619-5300
Indicator Light
F116299 ITEM 1
7025-01-545-6408
Data Entry Touchscreen
F1163
5999-00-937-9091
Delay Line
F11633-0000
8125-01-017-5701
Snap-on Cap Bottle
F11633-1
5340-01-102-5427
Loop Clamp
F11634-1
5342-01-102-8308
Clamp
F11637
8125-00-089-5199
Applicator Bottle
F116383
2030-01-629-8224
Machinery Control Console
F116393
5930-01-643-4836
Switch Assembly
F1164-009
5310-00-227-4881
Spring Tension Washer
F1164-010
5310-01-032-3050
Spring Tension Washer
F116403
5930-01-641-4253
Switch Assembly
F116403 REV A ITEM 49
5930-01-641-5074
Rotary Switch
F116413
5930-01-629-8523
Switch Assembly