DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-386-8702 to receive an up to date pricing and availability quote by email.

5925-00-386-8702
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-386-8702
Item Name Code
00136
Assigment Date
03/25/1974 (52 years ago)

3.375 inches nominal body height, multipole-single actuator type body style, 5.062 inches nominal center to center distance between terminals parallel to length, 6.000 inches nominal body length, 4.125 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.000 inches nominal
Body Width
4.125 inches nominal
Body Height
3.375 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.062 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
Unthreaded Mounting Hole Diameter
0.187 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.500 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.125 inches nominal
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 minimum at 200 pct and 85.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
4994D95G23 Circuit Breaker
FB3110ML Circuit Breaker
FB3110MRL Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-386-8702?
The FSCG of the NSN 5925-00-386-8702 is 5925
Does the NSN 5925-00-386-8702 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-386-8702 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-386-8702 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-386-8702 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-386-8702 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Mon, Mar 25, 1974

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

TA-1029/FSC
5965-01-167-2269
Handset
TA-103
5975-00-903-8857
Electrical Conduit Adapter
TA-103(V)
5985-01-292-2954
Antenna Assembly
TA-1030/FSC
5965-01-165-7496
Handset
TA-1032/ASC-33(V(
5895-01-206-0675
Communication Equ Interface Unit
TA-1034/ASC-33
5895-01-205-8357
Communication Equ Interface Unit
TA-1035/U
5805-01-246-6826
Telephone Set
TA-1036-A
5342-00-523-8318
Carrying Strap
TA-1037/A
5805-01-323-0665
Selector Telephone Switch
TA-1041/TYQ
5805-01-280-3601
Telephone Set
TA-1042A/U
5805-01-318-8421
Telephone Set
TA-1048
4730-01-419-2490
Pipe to Hose Straight Adapter
TA-1048-P
4730-01-419-2490
Pipe to Hose Straight Adapter
TA 10499160
4540-01-049-9160
Immer Electrical Heating Element
TA-105
3110-01-244-8662
Annular Ball Bearing