DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-348-3591 to receive an up to date pricing and availability quote by email.

5925-00-348-3591
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-348-3591
Item Name Code
00136
Assigment Date
01/24/1974 (52 years ago)

0.531 inches minimum and 0.593 inches maximum body width, 0.219 inches minimum and 0.281 inches maximum bushing length, 0.719 inches minimum and 0.781 inches maximum body length, single pole type body style, 0.672 inches minimum and 0.734 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.219 inches minimum and 0.281 inches maximum
Body Length
0.719 inches minimum and 0.781 inches maximum
Body Width
0.531 inches minimum and 0.593 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.672 inches minimum and 0.734 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.919 inches minimum and 1.981 inches maximum
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac and 7.5 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac and 5000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.469 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
vibrationproof and fungus resistant and moisture resistant
Trip Release Ambient Temp Rating
25.0 celsius maximum single location
Unpackaged Unit Weight
38.0 grams nominal
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
uns
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
7274-21-7 1/2 Circuit Breaker
BACC18U7 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-348-3591?
The FSCG of the NSN 5925-00-348-3591 is 5925
Does the NSN 5925-00-348-3591 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-348-3591 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-348-3591 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-348-3591 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-348-3591 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Thu, Jan 24, 1974

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

T101B
5945-00-768-7255
Electromagnetic Relay
T101C
5950-00-187-4611
Power Transformer
T101K99U2JW8570
5910-00-107-0155
Ceramic Dielectr Fixed Capacitor
T101KZQE
5930-01-505-9508
Toggle Switch
T101LH9V3BE
5930-01-207-9528
Toggle Switch
T101MH9AVBE
5930-01-568-4046
Toggle Switch
T101MH9V3B
5930-01-344-1627
Toggle Switch
T101MT-WHI012M
7010-01-594-3052
Digital Computer System
T101R
6740-00-464-9203
Photographic Chemica Mixing Tank
T101RGRSPECIAL
3110-00-293-9332
Thrust Ball Bearing
T101SERIE212
5930-01-028-4295
Rotary Switch Section
T101SHZQE
5930-01-344-3935
Toggle Switch
T101STDCBE
5930-01-544-8125
Toggle Switch
T101U3
5950-00-805-0745
Power Transformer
T101W
3110-00-117-0754
Thrust Roller Bearing