1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-306-2826

5925-00-306-2826

Find complete technical information, availability, and procurement data for: 5925-00-306-2826

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-306-2826 to receive an up to date pricing and availability quote by email.

5925-00-306-2826
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-306-2826
Item Name Code
00136
Assigment Date
10/17/1973 (52 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

0.730 inches minimum and 0.780 inches maximum body width, +0.1177 to 0.1214 inches thread pitch diameters, 2.510 inches maximum body length, single pole type body style, 1.660 inches minimum and 1.960 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.1177 to 0.1214 inches
Body Style
single pole type
Body Length
2.510 inches maximum
Body Width
0.730 inches minimum and 0.780 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Boss Height
0.109 inches minimum and 0.171 inches maximum
Mounting Surface To Terminal End Distance
2.800 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.135 minimum at 200 pct and 1.850 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Frequency In Hertz
60.0 single location
Material
plastic case
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud
Specification/Standard Data
81349-mil-c-55629/2 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-137-8722 No Name Available 05/01/1988
5925-00-683-8058 No Name Available 08/01/1982

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
129-203-101 Circuit Breaker
3007869-65 Circuit Breaker
AM12HKMG6-3-250VAC60C5 Circuit Breaker
APL1-1R0-55629-2-032 Circuit Breaker
APL1-1R0-61-302-M Circuit Breaker
M55629/2-032 Circuit Breaker
MIL-PRF-55629/2D Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-306-2826?
The FSCG of the NSN 5925-00-306-2826 is 5925
Does the NSN 5925-00-306-2826 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-306-2826 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-306-2826 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-306-2826 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-306-2826 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Wed, Oct 17, 1973

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

262-0666-00
6210-00-578-6928
Indicator Light
262-0669-00
5930-00-106-4834
Rotary Switch
262-0673-00
5930-00-798-3850
Rotary Switch
262-0674-00
5930-00-834-5237
Rotary Switch
262-0677-00
6625-00-613-8625
Electronic Switch
262-0678-00
6625-00-613-8628
Electrical Test Set Subassembly
262-0679-000
6240-00-731-5071
Glow Lamp
262-0680-00
6240-00-682-3411
Glow Lamp
262-0682-000
6210-00-729-9661
Light Lens
262-0687-00
5820-00-498-4366
Switch Rotary Wired
262-0687-03
5930-01-024-3576
Wired Rotary Switch
262-0690-00
6250-00-779-3680
Lampholder Holder
262-0690-000
6250-00-779-3680
Lampholder Holder
262-0693-02
6625-00-377-9984
Electrical Test Set Subassembly
262-0693-04
5930-00-156-3346
Rotary Switch