Find complete technical information, availability, and procurement data for: 5925-00-306-2818

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-306-2818 to receive an up to date pricing and availability quote by email.

5925-00-306-2818
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-306-2818
Item Name Code
00136
Assigment Date
10/17/1973 (52 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

1.660 inches minimum and 1.960 inches maximum center to center distance between terminals parallel to length, 2.510 inches maximum body length, multipole-multiple actuator type body style, 2.205 inches minimum and 2.285 inches maximum body width, +0.1177 to 0.1214 inches thread pitch diameters

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.1177 to 0.1214 inches
Body Style
multipole-multiple actuator type
Body Length
2.510 inches maximum
Body Width
2.205 inches minimum and 2.285 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.553 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
6 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
9.000 minimum at 200 pct and 150.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and salt spray proof and shock resistant and vibration resistant
Frequency In Hertz
400.0 all locations
Material
plastic case
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud
Specification/Standard Data
81349-mil-c-55629/5 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-078-6475 No Name Available 11/01/1991
5925-00-417-0539 No Name Available 05/01/1984

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
260-4012-620 Circuit Breaker
632237-243 Circuit Breaker
AM333MG6-243 Circuit Breaker
AM333MG6-35-250VAC400C14 Circuit Breaker
APL-111-1-43-353-M Circuit Breaker
APL-111-55629/5-126 Circuit Breaker
APL111-516-620 Circuit Breaker
M55629/5-126 Circuit Breaker
M55629/5-126L Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-306-2818?
The FSCG of the NSN 5925-00-306-2818 is 5925
Does the NSN 5925-00-306-2818 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-306-2818 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-306-2818 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-306-2818 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-306-2818 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Wed, Oct 17, 1973

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

LM-1511R
7025-01-571-6010
Display Unit
LM 1782
5340-01-564-3504
Protector-Bld Vert
LM 1821
4920-01-564-3505
Test Block Adapter
LM 1847
4920-01-564-4133
Aircraft Maintenance Fixture
LM-19-P
5950-01-535-9838
Power Transformer
LM-19340
6130-01-330-4875
Power Supply
LM 1946
4920-01-564-3506
Aircraft Maintenance Template
LM 1994
4920-01-564-3507
Test Block Adapter
LM-1B-95R/WL
3010-01-557-1628
Reduction Ge Oil Pressure Sensor
LM-1BB-120R/WL
5930-01-507-1443
Pressure Switch
LM-2
6240-01-274-0192
Incandescent Lamp
LM 2-12278-01
5998-01-103-2099
Circuit Card Assembly
LM 2-12278-03
5998-01-103-2100
Circuit Card Assembly
LM 2-12278-08
5998-01-103-2101
Circuit Card Assembly
LM 2-12280-02
5998-01-103-2030
Electronic Components Assembly