5925-00-283-6511

Find complete technical information, availability, and procurement data for: 5925-00-283-6511

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-283-6511 to receive an up to date pricing and availability quote by email.

5925-00-283-6511
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-283-6511
Item Name Code
00136
Assigment Date
01/01/1963 (63 years ago)

0.969 inches nominal center to center distance between terminals parallel to length, 2.000 inches nominal overall length, 0.156 inches nominal unthreaded mounting hole diameter, single pole type body style, 1.250 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Overall Length
2.000 inches nominal
Body Width
1.250 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.969 inches nominal
Unthreaded Mounting Hole Diameter
0.156 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.625 inches nominal
Mounting Surface To Terminal End Distance
1.375 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac and 25.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
30.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
600.0 ac and 600.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
automatic
Internal Trip Release Configuration
series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current
11.000 minimum at 200 pct and 190.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
weatherproof
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Frequency In Hertz
60.0 single location
Material
plastic case
Terminal Type And Quantity
2 screw

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-140-3246 No Name Available 01/05/1972
5925-00-175-5196 No Name Available 10/11/1967
5925-00-501-6599 No Name Available 05/01/1976
5925-00-502-2287 No Name Available 10/01/1984
5925-01-080-0038 No Name Available 11/24/2003

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
5925002836511 Circuit Breaker
701221 Circuit Breaker
7974397 Circuit Breaker
CDA-25AMP Circuit Breaker
PA25 Circuit Breaker
PDA-25 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-283-6511?
The FSCG of the NSN 5925-00-283-6511 is 5925
Does the NSN 5925-00-283-6511 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-283-6511 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-283-6511 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-283-6511 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-283-6511 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

A05622-091
6220-01-357-9496
Indicator Light
A05622-099
6220-01-357-9497
Indicator Light
A05622-101
5930-01-355-1552
Push Switch
A05622-102
5930-01-355-1553
Push Switch
A05622-103
5930-01-355-1554
Push Switch
A05622-104
5930-01-355-1555
Push Switch
A05622-105
5930-01-355-1556
Push Switch
A05622-106
5930-01-355-1557
Push Switch
A05622-107
6220-01-355-6302
Indicator Light
A05622-108
6220-01-355-6303
Indicator Light
A05622-109
5930-01-355-1558
Push Switch
A05622-110
5930-01-355-1559
Push Switch
A05622-111
5930-01-355-1560
Push Switch
A05622-113
5930-01-355-7121
Push Switch
A05622-114
5930-01-355-1562
Push Switch