1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-258-9814

5925-00-258-9814

Find complete technical information, availability, and procurement data for: 5925-00-258-9814

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-258-9814 to receive an up to date pricing and availability quote by email.

5925-00-258-9814
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-258-9814
Item Name Code
00136
Assigment Date
01/01/1963 (63 years ago)

single pole type body style, 6.000 inches nominal body length, 3.219 inches nominal body height, 4.594 inches nominal center to center distance between terminals parallel to length, 1.500 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
6.000 inches nominal
Body Width
1.500 inches nominal
Body Height
3.219 inches nominal
Center To Center Distance Between Terminals Parallel To Length
4.594 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.984 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
3 threaded stud
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac and 15.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac and 125.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac and 5000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.164 inches
Trip Delay Time In Seconds Per Rated Continuous Current
100.000 nominal at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 screw

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-655-3341 No Name Available 01/01/1960
5925-00-755-0741 No Name Available 07/01/1976
5925-00-933-2604 No Name Available 07/01/1976

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
9968172 Circuit Breaker
EE1B015 Circuit Breaker
ET1151 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-258-9814?
The FSCG of the NSN 5925-00-258-9814 is 5925
Does the NSN 5925-00-258-9814 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-258-9814 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-258-9814 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-258-9814 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-258-9814 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

357-9237-00
5935-00-740-2207
Electrical Plug Connector
357-9237-000
5935-00-740-2207
Electrical Plug Connector
357-9239-00
5935-00-581-2380
Electrical Plug Connector
357-9239-000
5935-00-581-2380
Electrical Plug Connector
357-9247-000
5935-00-687-1686
Connector Adapter
357-9248-00
5935-00-518-9044
Electrical Plug Connector
357-9248-000
5935-00-518-9044
Electrical Plug Connector
357-9248-010
5935-00-810-3767
Electrical Receptacle Connector
357-9249-00
5935-00-655-1243
Connector Adapter
357-9249-000
5935-00-655-1243
Connector Adapter
357-9257-00
5935-00-801-5424
Electrical Receptacle Connector
357-9258-000
5935-00-836-6523
Electrical Receptacle Connector
357-9260-00
5935-00-067-4191
Electrical Connector Backshell
357-9260-000
5935-00-067-4191
Electrical Connector Backshell
357-9261-00
5935-00-577-8776
Electrical Plug Connector