5925-00-236-1941

Find complete technical information, availability, and procurement data for: 5925-00-236-1941

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-236-1941 to receive an up to date pricing and availability quote by email.

5925-00-236-1941
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-236-1941
Item Name Code
00136
Assigment Date
10/27/1969 (56 years ago)

+0.3503 to 0.3537 inches thread pitch diameters, 1.937 inches maximum body width, 0.380 inches maximum bushing length, 1.562 inches maximum body length, multipole-single actuator type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.3503 to 0.3537 inches
Body Style
multipole-single actuator type
Bushing Length
0.380 inches maximum
Body Length
1.562 inches maximum
Body Width
1.937 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.780 inches maximum
Pole Quantity
3
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
1.0 amperes dc third location
Maximum Continuous Load Current Rating Per Pole
1.5 amperes dc first location
Maximum Continuous Load Current Rating Per Pole
1.5 amperes dc second location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.007 minimum at 200 pct and 0.025 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
hermetically sealed and shockproof and vibrationproof
Unpackaged Unit Weight
5.400 ounces nominal
Thread Series Designator
unef
Terminal Type And Quantity
6 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AP112R191-8 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-236-1941?
The FSCG of the NSN 5925-00-236-1941 is 5925
Does the NSN 5925-00-236-1941 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-236-1941 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-236-1941 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-236-1941 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-236-1941 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Mon, Oct 27, 1969

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

IN3504
5820-01-472-5044
Audio-Video Switching Unit
IN350450XN
5310-01-700-6478
Flat Washer
IN3505
5820-01-416-8230
Audio-Video Switching Unit
IN3506
5820-01-496-3340
Audio-Video Switching Unit
IN3510
5820-01-393-2053
Audio-Video Switching Unit
IN3520
5836-01-395-6378
Audio-Video Switching Unit
IN3526VI
5820-01-657-4515
Audio-Video Switching Unit
IN3535288XN
5310-01-714-2620
Lock Washer
IN353528XN
5310-01-714-2606
Lock Washer
IN3535420XN
5310-01-692-1599
Lock Washer
IN3535460XN
5310-01-692-1600
Lock Washer
IN3535481XN
5310-01-692-1598
Lock Washer
IN3535485XN
5310-01-691-5229
Lock Washer
IN3552
5836-01-469-0851
Audio-Video Switching Unit
IN3556
5836-01-537-3640
Audio-Video Switching Unit