1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-189-9591

5925-00-189-9591

Find complete technical information, availability, and procurement data for: 5925-00-189-9591

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-189-9591 to receive an up to date pricing and availability quote by email.

5925-00-189-9591
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-189-9591
Item Name Code
00136
Assigment Date
03/18/1973 (53 years ago)

1.938 inches nominal center to center distance between terminals parallel to length, 2.500 inches nominal body length, 0.750 inches nominal body width, single pole type body style, +0.1177 to 0.1214 inches thread pitch diameters

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.1177 to 0.1214 inches
Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.611 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
22.000 minimum at 200 pct and 85.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof and fungus proof
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
274-230-101 Circuit Breaker
4MC2-205-30 Circuit Breaker
AM12-30-250-400-14 Circuit Breaker
APL1-103-32 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-189-9591?
The FSCG of the NSN 5925-00-189-9591 is 5925
Does the NSN 5925-00-189-9591 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-189-9591 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-189-9591 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-189-9591 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-189-9591 was assigned to the Federal Catalog?
It was assigned 53 years ago, on Sun, Mar 18, 1973

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

6052223
5930-01-553-1987
Push Switch
6052228
5930-01-553-0307
Toggle Switch
6052229
5930-01-553-0308
Push Switch
6052230
5930-01-452-8230
Push Switch
6052232
5930-01-553-1990
Switch Assembly
605224
3120-00-678-9157
Self-Aligning Plain Bearing
605224-1
5998-00-404-1192
Circuit Card Assembly
605224-2
5998-01-293-8964
Circuit Card Assembly
605225
5930-01-618-6627
Switch Subassembly
605225-1
5841-00-097-8725
Radar Set Subassembly
605225-2
5841-00-001-5605
Radar Set Subassembly
6052258
6240-01-553-3154
Incandescent Lamp
605227
2910-00-355-0913
Filt Fuel Line Assy
605227-479
5905-00-984-7920
Wire Wound Fixed Resistor
6052278
4720-01-610-8264
Preformed Hose