DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-186-0765 to receive an up to date pricing and availability quote by email.

5925-00-186-0765
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-186-0765
Item Name Code
00136
Assigment Date
03/19/1971 (55 years ago)

0.750 inches nominal center to center distance between terminals parallel to length, single pole type body style, 2.500 inches nominal body length, 0.750 inches nominal body width, 2.062 inches nominal distance between centerlines of mounting facilities parallel to body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.471 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Ultimate Trip Time Per Pole In Seconds
10.000 minimum and 70.000 maximum single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
9.000 maximum at 200 pct and 3.000 minimum at 200 pct and 0.900 minimum at 300 pct and 3.100 maximum at 300 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
5.0 dc
Switch Voltage Rating And Type In Volts
125.0 dc
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
70-123-10MG6 Circuit Breaker
L219716-10 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-186-0765?
The FSCG of the NSN 5925-00-186-0765 is 5925
Does the NSN 5925-00-186-0765 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-186-0765 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-186-0765 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-186-0765 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-186-0765 was assigned to the Federal Catalog?
It was assigned 55 years ago, on Fri, Mar 19, 1971

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

044.044.01
5305-01-444-3810
Socket Head Cap Screw
044-047
3431-01-172-5421
Gas Valve
044-049-00
5930-01-377-0580
Sensitive Switch
044-05-013
6760-01-074-5569
Photographic Lens Barrel
044-0570-00
5365-00-829-5869
Machine Thread Plug
044-0580-00
4210-00-829-5882
Valve Cover
044-0580-00-0
4210-00-829-5882
Valve Cover
044-0600-0
4320-01-408-5699
Pump-Motor Hydraulic Cover
044-0600-01-0
4320-01-408-5699
Pump-Motor Hydraulic Cover
044-0601-0
4320-01-447-8097
Pump Water Jacket
044-0601-1
4320-01-378-9275
Centrifugal Pump
044-0663-99
5945-00-502-9627
Electromagnetic Relay
044-072
5905-00-019-8223
Resistor,variable,nonwire Wound,
044-07511-000
5340-01-205-3877
Lock-Release Lever
044-07523-000
5340-01-184-3487
Manual Control Lever