5925-00-169-9829

Find complete technical information, availability, and procurement data for: 5925-00-169-9829

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-169-9829 to receive an up to date pricing and availability quote by email.

5925-00-169-9829
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-169-9829
Item Name Code
00136
Assigment Date
08/25/1972 (53 years ago)

0.130 inches nominal bushing length, 2.000 inches nominal body length, multipole-multiple actuator type body style, 2.500 inches nominal body width, 1.560 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Bushing Length
0.130 inches nominal
Body Length
2.000 inches nominal
Body Width
2.500 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Mounting Surface To Terminal End Distance
2.210 inches maximum
Pole Quantity
3
Mounting Facility Type And Quantity
6 threaded hole
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole
50.0 milliamperes dc third location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
instantaneous and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Internal Trip Release Configuration
relay trip third location
Internal Trip Release Configuration
series trip first location
Internal Trip Release Configuration
series trip second location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
8 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
5042-460 Circuit Breaker
FHD30-002-2 Circuit Breaker
JA3A3A3B6 Circuit Breaker
JA3A3A3B6LC30A25060C2R0-05A30DCP Circuit Breaker
JA3S-Z69-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-169-9829?
The FSCG of the NSN 5925-00-169-9829 is 5925
Does the NSN 5925-00-169-9829 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-169-9829 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-169-9829 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-169-9829 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-169-9829 was assigned to the Federal Catalog?
It was assigned 53 years ago, on Fri, Aug 25, 1972

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

748-1121-000
5905-00-993-6842
Wire Wound Fixed Resistor
748-1122-00
5905-00-912-7855
Wire Wound Fixed Resistor
748-1247-070
5905-00-932-0001
Wire Wound Fixed Resistor
748-1248-010
5905-00-975-8375
Wire Wound Fixed Resistor
748-1248-020
5905-00-975-8378
Wire Wound Fixed Resistor
748-1248-030
5905-00-975-8384
Wire Wound Fixed Resistor
748-1248-040
5905-00-975-8385
Wire Wound Fixed Resistor
748-1248-050
5905-00-975-8402
Wire Wound Fixed Resistor
748-1248-060
5905-00-975-8409
Wire Wound Fixed Resistor
748-1248-070
5905-00-975-8427
Wire Wound Fixed Resistor
748-1248-080
5905-00-975-8434
Wire Wound Fixed Resistor
748-1248-090
5905-00-975-8445
Wire Wound Fixed Resistor
748-1248-100
5905-00-975-8454
Wire Wound Fixed Resistor
748-1248-110
5905-00-975-8479
Wire Wound Fixed Resistor
748-1248-120
5905-00-975-8494
Resistor,fixed,wire Wound,induct