DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part AP1R2AMPD1 to receive an up to date pricing and availability quote by email.

AP1R2AMPD1
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-135-6136
Item Name Code
00136
Assigment Date
01/15/1969 (57 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

0.280 inches minimum and 0.380 inches maximum bushing length, 1.562 inches maximum body length, 0.625 inches maximum body width, single pole type body style, +0.3503 to 0.3537 inches thread pitch diameters

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.3503 to 0.3537 inches
Body Style
single pole type
Bushing Length
0.280 inches minimum and 0.380 inches maximum
Body Length
1.562 inches maximum
Body Width
0.625 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.700 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Ultimate Trip Time Per Pole In Seconds
0.200 minimum and 7.000 maximum single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct and 0.950 maximum at 200 pct and 0.240 maximum at 400 pct single location
Inclosure Protection Type For Which Designed
fungus resistant
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
Test Data Document
"81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unef
Terminal Type And Quantity
2 wire hook
Specification/Standard Data
81349-mil-c-39019/2 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-982-6551 No Name Available 11/01/1984
5925-01-011-9985 No Name Available 09/24/1996

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
10 356 831 Circuit Breaker
125-81-3 Circuit Breaker
352250009121 Circuit Breaker
352250009123 Circuit Breaker
7644929P004 Circuit Breaker
7644929P4 Circuit Breaker
AP1R2AMPD1 Circuit Breaker
AP1R66-4 Circuit Breaker
M39019/02-218 Circuit Breaker
M39019/2-218 Circuit Breaker
M39019/2-81 Circuit Breaker
M39019/2-85 Circuit Breaker
MIL-PRF-39019/2 Circuit Breaker
SM3HK2-0-50DC Circuit Breaker
SM3HK2-50VDC2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-135-6136?
The FSCG of the NSN 5925-00-135-6136 is 5925
Does the NSN 5925-00-135-6136 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-135-6136 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-135-6136 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-135-6136 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-135-6136 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Wed, Jan 15, 1969

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

81-S-102-3
4320-01-391-8375
Jet Ejector
81-S-102-4
4320-01-633-9277
Jet Ejector
81-S-102-4A
4320-01-633-9277
Jet Ejector
81-S-1797
5950-01-431-3697
Power Transformer
81-T 1 1/4IN
4820-01-338-4269
Globe Valve
81-T1-1/4 IN
4820-01-207-1011
Globe Valve
81-T1/2IN
4820-01-207-9513
Globe Valve
81-T1/4 IN
4820-01-207-5954
Globe Valve
81 TIP
3433-01-690-7524
Cutting Torch Tip
81-TM-06401-S
5340-01-371-9327
Swivel Caster
81-X3.5
4940-01-124-5914
Electromagnetic Shield Enclosure
81-X6
4940-01-125-3832
Electromagnetic Shield Enclosure
81-X7.5
4940-01-124-5915
Electromagnetic Shield Enclosure
810
1560-00-136-7990
Tank Foam Kit
810-00
5330-01-205-4248
Plain Seal