Find complete technical information, availability, and procurement data for: 5925-00-123-9919

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-123-9919 to receive an up to date pricing and availability quote by email.

5925-00-123-9919
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-123-9919
Item Name Code
00136
Assigment Date
11/08/1968 (57 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

general purpose warehouse storage type, 30.0 amperes ac all locations maximum continuous load current rating per pole, 3 pole quantity, 4 unthreaded hole mounting facility type and quantity, 0.172 inches nominal unthreaded mounting hole diameter

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Unthreaded Mounting Hole Diameter
0.172 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
100.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Internal Trip Release Configuration
series trip all locations
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 minimum at 200 pct and 100.000 maximum at 200 pct all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
FAL36030 Circuit Breaker
HDL36030 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-123-9919?
The FSCG of the NSN 5925-00-123-9919 is 5925
Does the NSN 5925-00-123-9919 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-123-9919 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-123-9919 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-123-9919 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-123-9919 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Fri, Nov 8, 1968

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

000-8003-604
5940-01-230-2041
Ferrule,metallic Shielded Cable,
000-8003-685
5935-01-170-0486
Electrical Receptacle Connector
000-8003-691
5935-01-050-5408
Electrical Plug Connector
000-8003-692
5935-00-531-9539
Electrical Plug Connector
000-8003-701
6145-00-027-5955
Electrical Wire
000-8003-710
5930-01-257-1216
Toggle Switch
000-8003-712
5920-01-191-9844
Extractor Post Fuseholder
000-8003-716
5935-01-150-3519
Tip Jack
000-8003-717
5998-01-080-0960
Electrical Card Holder
000-8003-736
5930-01-253-4221
Push Switch
000-8003-776
5925-01-157-4601
Circuit Breaker
000-8003-778
5950-01-250-8907
Power Transformer
000-8003-781
6145-01-007-4701
Electrical Wire
000-8003-783
5962-01-068-7842
Digital Microcircuit
000-8003-786
5945-01-231-5843
Reed Relay