5925-00-050-7649
Find complete technical information, availability, and procurement data for: 5925-00-050-7649
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-050-7649 to receive an up to date pricing and availability quote by email.
"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."
0.740 inches minimum and 0.760 inches maximum body width, 2.052 inches minimum and 2.072 inches maximum distance between centerlines of mounting facilities parallel to body length, 1.928 inches minimum and 1.948 inches maximum center to center distance between terminals parallel to length, 2.490 inches minimum and 2.510 inches maximum body length, single pole type body style
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Body Style
- single pole type
- Body Length
- 2.490 inches minimum and 2.510 inches maximum
- Body Width
- 0.740 inches minimum and 0.760 inches maximum
- Center To Center Distance Between Terminals Parallel To Length
- 1.928 inches minimum and 1.948 inches maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
- 2.052 inches minimum and 2.072 inches maximum
- Switch Contact Arrangement
- single pole, double throw
- Fragility Factor
- moderately rugged
- Boss Height
- 0.130 inches minimum and 0.150 inches maximum
- Mounting Surface To Terminal End Distance
- 2.461 inches minimum and 2.481 inches maximum
- Pole Quantity
- 1
- Arc Quenching Method
- magnetic blowout
- Mounting Facility Type And Quantity
- 2 threaded hole
- Thread Quantity Per Inch
- 32
- Maximum Continuous Load Current Rating Per Pole
- 10.0 amperes ac single location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac single location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1000.0 ac single location
- Circuit Protection Type
- overcurrent single location
- Trip Release Method
- magnetic-hydraulic single location
- Trip Release Characteristic
- time delay single location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 150.0 single location
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 1 toggle
- Actuator Function
- trip-reset
- Actuator Position Designation
- at pole one
- Auxiliary Switch Function And Quantity
- 1 alarm
- Internal Trip Release Configuration
- series trip single location
- Nominal Thread Size
- 0.138 inches
- Switch Location And Position Designation
- external at pole one
- Trip Delay Time In Seconds Per Rated Continuous Current
- 1.500 minimum at 200 pct and 7.500 maximum at 200 pct single location
- Inclosure Protection Type For Which Designed
- dustproof
- Switch Terminal Type
- threaded stud
- Switch Current Rating And Type In Amps
- 10.0 ac
- Switch Voltage Rating And Type In Volts
- 250.0 ac
- Frequency In Hertz
- 400.0 single location
- Material
- plastic case
- Thread Series Designator
- unc
- Terminal Type And Quantity
- 2 threaded stud
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 328C055H07 | Circuit Breaker |
| AM30MG6-10A | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-00-050-7649?
Does the NSN 5925-00-050-7649 have a Schedule B code assigned?
Does NSN 5925-00-050-7649 require demilitarization?
Does NSN 5925-00-050-7649 contain precious materials?
Does NSN 5925-00-050-7649 contain hazardous materials?
When the NSN 5925-00-050-7649 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections