1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-006-3539

5925-00-006-3539

Find complete technical information, availability, and procurement data for: 5925-00-006-3539

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-006-3539 to receive an up to date pricing and availability quote by email.

5925-00-006-3539
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-006-3539
Item Name Code
00136
Assigment Date
06/16/1972 (54 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

1.660 inches nominal distance between centerlines of mounting facilities parallel to body length, 0.750 inches nominal body width, 2.000 inches nominal body length, 1.560 inches nominal center to center distance between terminals parallel to length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.000 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
Boss Height
0.130 inches nominal
Mounting Surface To Terminal End Distance
1.880 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.170 minimum at 200 pct and 1.900 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Unpackaged Unit Weight
3.000 ounces nominal
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 quick disconnect, male

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
C300-017 Circuit Breaker
JAIC3-1-0-3A Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-006-3539?
The FSCG of the NSN 5925-00-006-3539 is 5925
Does the NSN 5925-00-006-3539 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-006-3539 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-006-3539 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-006-3539 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-006-3539 was assigned to the Federal Catalog?
It was assigned 54 years ago, on Fri, Jun 16, 1972

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

XM-79665-87L56-2.7U31-5.1OL316
6680-01-326-8828
Liquid Quantity Transmitter
XM-79665-87L56-2.7U31-5.1WL316
6680-01-326-8828
Liquid Quantity Transmitter
XM-79665-87L71-2.7U16-1.5OL316
6680-01-327-7925
Liquid Quantity Transmitter
XM-79665-87L71-2.7U16-1.5WL316
6680-01-327-7925
Liquid Quantity Transmitter
XM-79665-90-0510-W-L
6680-01-275-5101
Liquid Quantity Transmitter
XM-79665-92-6200-W-H
6680-01-491-3553
Liquid Quantity Transmitter
XM-79665-92L18-3.6U74-6.2OL316
6680-01-326-4208
Liquid Quantity Transmitter
XM-79665-92L18-3.6U74-6.2WL316
6680-01-326-4208
Liquid Quantity Transmitter
XM-79665-95-0510-W-L
6680-01-394-0136
Liquid Quantity Transmitter
XM-79665-96-0510-W-L
6680-01-275-5102
Liquid Quantity Transmitter
XM-79665 REV E
5895-01-630-1441
Transmitter Control Group
XM-79665 REV E/198862
6680-01-609-0794
Rate of Flow Transmitter
XM-79665 REV E/199262
6680-01-609-1724
Rate of Flow Transmitter
XM-79665 REV E/199266
6680-01-609-1496
Rate of Flow Transmitter
XM-79665 REV E/199517
6680-01-608-8063
Liquid Quantity Transmitter