1. Home /
  2. Catalog /
  3. Capacitors /
  4. 5910-01-246-4504

5910-01-246-4504

Find complete technical information, availability, and procurement data for: 5910-01-246-4504

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5910-01-246-4504 to receive an up to date pricing and availability quote by email.

5910-01-246-4504
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5910 Capacitors
National Stock Number
5910-01-246-4504
Item Name Code
00007
Assigment Date
12/13/1986 (39 years ago)

A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

0.148 inches nominal terminal length, established reliability indicator, dual inline body style, 0.010 reliability failure rate level in percent, 0.092 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
dual inline
Reliability Indicator
established
Reliability Failure Rate Level In Percent
0.010
Terminal Length
0.148 inches nominal
Body Length
0.092 inches nominal
Body Width
0.260 inches nominal
Body Height
0.283 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.325 inches nominal
Schematic Diagram Designator
no common or grounded electrode(s)
Insulation Resistance At Maximum Operating Temp
10000.0 megohms
Capacitance Value Per Section
470000.000 picofarads single section
Voltage Temp Limits Per Section In Percent Capacitance Change
-40.0 to 15.0 with rated voltage applied single section
Nonderated Operating Temp
-55.0 celsius minimum and 125.0 celsius maximum
Nonderated Continuous Voltage Rating And Type Per Section
50.0 dc single section
Tolerance Range Per Section
-10.00 to 10.00 percent single section
Insulation Resistance At Reference Temp
100000.0 megohms
Dissipation Factor At Reference Temp In Percent
3.000
Terminal Surface Treatment
solder
Material
plastic case
Test Data Document
"81349-mil-c-39014 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
2 printed circuit
Specification/Standard Data
81349-mil-c-39014/22 government specification

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
M39014/22-0850 Ceramic Dielectr Fixed Capacitor

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5910-01-246-4504?
The FSCG of the NSN 5910-01-246-4504 is 5910
Does the NSN 5910-01-246-4504 have a Schedule B code assigned?
Yes, the Schedule B code is 8532290040
Does NSN 5910-01-246-4504 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5910-01-246-4504 contain precious materials?
Item does not contain precious metal.
Does NSN 5910-01-246-4504 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5910-01-246-4504 was assigned to the Federal Catalog?
It was assigned 39 years ago, on Sat, Dec 13, 1986

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

4140CK1E24AA0-EE
5930-01-678-4002
Pressure Switch
4140CK1H11AAO-ADZ
5930-01-567-2707
Pressure Switch
4140CK1H19AA0EE
5930-01-234-7284
Pressure Switch
4140CK3A41AA0-AFF 0.4 BARFALLING
5930-01-529-2687
Pressure Switch
4140CR1H11AA0-EE
5930-01-232-3616
Pressure Switch
4140CR1H11AAAOEE
5930-01-232-3616
Pressure Switch
4140CR3R44AA0EE 22.0 BAR RISING
5930-01-426-6816
Pressure Switch
4140D
5930-01-395-3766
Thermostatic Switch
4140DK1H00CE4EE
5930-01-567-2711
Thermostatic Switch
4140DK1H00CL6EE
5930-01-594-1162
Spec Temp Switch Re
4140DR1E00CE5-EE
5930-01-564-7084
Thermostatic Switch
4140DR1G00CA1EE 16DEGC FALLING
5930-01-426-7919
Pressure Switch
4140DR1H00CA1EE 16DEGC FALLING
5930-01-426-7919
Pressure Switch
4140DR1HOOCF4EE
5930-01-232-3617
Thermostatic Switch
4140EK1E00CE1EE
5930-01-514-5890
Thermostatic Switch