283-0648-00

View detailed technical data, stock status, and sourcing information for: 283-0648-00

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 283-0648-00 to receive an up to date pricing and availability quote by email.

283-0648-00
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5910 Capacitors
National Stock Number
5910-01-029-0728
Item Name Code
00005
Assigment Date
10/16/1976 (49 years ago)

A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

0.270 inches maximum body length, 1.000 inches minimum terminal length, w/o mtg facilities terminal(s) on one surface body style, 0.0100 reliability failure rate level in percent, established reliability indicator

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
w/o mtg facilities terminal(s) on one surface
Reliability Indicator
established
Reliability Failure Rate Level In Percent
0.0100
Terminal Length
1.000 inches minimum
Body Length
0.270 inches maximum
Body Width
0.190 inches maximum
Body Height
0.110 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.120 inches nominal
Terminal Diameter
0.016 inches nominal
Schematic Diagram Designator
no common or grounded electrode(s)
Insulation Resistance At Maximum Operating Temp
10000.0 megohms
Capacitance Value Per Section
10.000 picofarads single section
Nonderated Operating Temp
-55.0 celsius minimum and 125.0 celsius maximum
Nonderated Continuous Voltage Rating And Type Per Section
300.0 dc single section
Temp Coefficient Of Capacitance Range Per Section In Ppm Per Deg Celsius
-200.0 to 200.0 single section
Tolerance Range Per Section
-0.50 to 0.50 picofarads single section
Insulation Resistance At Reference Temp
100000.0 megohms
Dissipation Factor At Reference Temp In Percent
0.0055
Terminal Surface Treatment
solder
Material
plastic case
Test Data Document
"81349-mil-c-39001 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
2 uninsulated wire lead
Specification/Standard Data
81349-mil-c-39001/5 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5910-00-244-7798 No Name Available 07/01/1992
5910-00-329-7152 No Name Available 06/01/2007
5910-01-089-6939 No Name Available 09/01/1981
5910-01-098-3135 No Name Available 03/01/2008
5910-01-173-9898 No Name Available 10/01/1991

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
10128143 Mica Dielectric Fixed Capacitor
107173 Mica Dielectric Fixed Capacitor
283-0648-00 Mica Dielectric Fixed Capacitor
441-1197-035 Mica Dielectric Fixed Capacitor
740004-100 Mica Dielectric Fixed Capacitor
912-4141-021 Mica Dielectric Fixed Capacitor
CD6CA100J03 Mica Dielectric Fixed Capacitor
CMR03C100DOCL Mica Dielectric Fixed Capacitor
CMR03C100DOCP Mica Dielectric Fixed Capacitor
CMR03C100DOCR Mica Dielectric Fixed Capacitor
CMR05C100D0CM Mica Dielectric Fixed Capacitor
D151C100D0 Mica Dielectric Fixed Capacitor
DM5-100D Mica Dielectric Fixed Capacitor
DM5-100J Mica Dielectric Fixed Capacitor
DM5-100PF Mica Dielectric Fixed Capacitor
DM5C100D300WV Mica Dielectric Fixed Capacitor
DM5CC100J Mica Dielectric Fixed Capacitor
DM5CC100J04CR Mica Dielectric Fixed Capacitor
DM5EC100J0 Mica Dielectric Fixed Capacitor
DMSEC100J03 Mica Dielectric Fixed Capacitor
WDM5CA100J0 Mica Dielectric Fixed Capacitor

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5910-01-029-0728?
The FSCG of the NSN 5910-01-029-0728 is 5910
Does the NSN 5910-01-029-0728 have a Schedule B code assigned?
Yes, the Schedule B code is 8532290020
Does NSN 5910-01-029-0728 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5910-01-029-0728 contain precious materials?
Precious metal content is unknown
Does NSN 5910-01-029-0728 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5910-01-029-0728 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Sat, Oct 16, 1976

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

312-500
5920-00-280-8344
Cartridge Fuse
312-5012
5950-00-224-3621
Radio Frequency Transformer
312-5027-401
3040-01-234-1784
Shaft End Cover
312-5033-201
4320-01-279-0263
Pump-Motor Hydraulic Cover
312 5033 601
6150-01-278-9839
Electrical Rotating Equi Housing
312-5043-201
4320-01-281-5965
Pump-Motor Hydraulic Cover
312-50641
5935-01-267-6576
Tip Jack
312-510207
5915-01-722-4631
Direct Current Power Filter
312-510207-010
5915-01-722-4631
Direct Current Power Filter
312-510220
5895-01-722-2588
Indicator Panel
312-510220-010
5895-01-722-2588
Indicator Panel
312-520100-010
6150-01-722-4487
E Special Purpose Cable Assembly
312-5242-001
6625-01-073-8755
Fault Locating Indicator
312-53125
5935-00-851-8455
Electrical Receptacle Connector
312-53225
5935-00-897-8708
Connector Adapter